MCP๋กœ ์—ฐ๊ฒฐ โ†’

๊ณ„์‚ฐ ์ž…๋ ฅ

๊ณต์‹

Show calculation steps (1)
  1. Achieved Illuminance

    Achieved Illuminance: ์กฐ๋ช…๋ฅ (๋ฃจ๋ฉ˜๋ฒ•) ์กฐ๋ช… ๊ณ„์‚ฐ๊ธฐ

    Actual lux delivered by the rounded-up number of fixtures N.

๊ด‘๊ณ 

๊ฒฐ๊ณผ

ํ•„์š” ๊ธฐ๊ตฌ ์ˆ˜
15
๋“ฑ๊ธฐ๊ตฌ (์˜ฌ๋ฆผ ์ ์šฉ)
์ •ํ™•ํ•œ ์ˆ˜๋Ÿ‰ (์˜ฌ๋ฆผ ์ „) 14.88
์„ค์น˜ ์ด ๊ด‘์† 52,500 lm
๋‹ฌ์„ฑ ์กฐ๋„ 504 lux

๋ฃจ๋ฉ˜๋ฒ•์ด๋ž€?

๋ฃจ๋ฉ˜๋ฒ•(์˜์—ญ ๊ณต๋™๋ฒ•, zonal cavity method์ด๋ผ๊ณ ๋„ ํ•จ)์€ ์ˆ˜ํ‰ ์ž‘์—…๋ฉด์—์„œ ์›ํ•˜๋Š” ํ‰๊ท  ์กฐ๋„๋ฅผ ํ™•๋ณดํ•˜๋Š” ๋ฐ ํ•„์š”ํ•œ ์กฐ๋ช… ๊ธฐ๊ตฌ์˜ ๊ฐœ์ˆ˜๋ฅผ ์‚ฐ์ •ํ•˜๋Š” ํ‘œ์ค€ ์กฐ๋ช… ์„ค๊ณ„ ๊ธฐ๋ฒ•์ž…๋‹ˆ๋‹ค. ๋น›์ด ์ž‘์—…๋ฉด๊นŒ์ง€ ์–ผ๋งˆ๋‚˜ ํšจ์œจ์ ์œผ๋กœ ๋„๋‹ฌํ•˜๋Š”์ง€๋ฅผ ๋‚˜ํƒ€๋‚ด๋Š” ์กฐ๋ช…๋ฅ (CU)๊ณผ, ๋จผ์ง€๋‚˜ ๋žจํ”„ ๊ด‘์† ์ €ํ•˜๋กœ ์‹œ๊ฐ„์ด ์ง€๋‚จ์— ๋”ฐ๋ผ ์†์‹ค๋˜๋Š” ๋น›์˜ ์–‘์„ ๋‚˜ํƒ€๋‚ด๋Š” ๋ณด์ˆ˜์œจ(LLF)์„ ๋ชจ๋‘ ๊ณ ๋ คํ•ฉ๋‹ˆ๋‹ค.

Diagram of a room with a ceiling light fixture casting a cone of light onto a desk surface, showing some light absorbed by walls
The lumen method estimates the number of fixtures needed to reach a target illuminance on the work plane.

๊ณ„์‚ฐ๊ธฐ ์‚ฌ์šฉ ๋ฐฉ๋ฒ•

๋ชฉํ‘œ ์กฐ๋„(๋Ÿญ์Šค), ์‹ค๋‚ด ๋ฉด์ (์ œ๊ณฑ๋ฏธํ„ฐ), ์กฐ๋ช… ๊ธฐ๊ตฌ ํ•œ ๋Œ€์˜ ์ •๊ฒฉ ๊ด‘์†(๋ฃจ๋ฉ˜), ์กฐ๋ช…๋ฅ (CU), ๋ณด์ˆ˜์œจ(LLF)์„ ์ž…๋ ฅํ•˜์„ธ์š”. ๊ณ„์‚ฐ๊ธฐ๋Š” ํ•„์š”ํ•œ ์ด ๊ด‘์†์„ ๊ธฐ๊ตฌ ํ•œ ๋Œ€๊ฐ€ ์‹ค์ œ๋กœ ๊ณต๊ธ‰ํ•˜๋Š” ์œ ํšจ ๊ด‘์†์œผ๋กœ ๋‚˜๋ˆˆ ๋’ค, ์ •์ˆ˜ ๋‹จ์œ„์˜ ๋“ฑ๊ธฐ๊ตฌ ์ˆ˜๋กœ ์˜ฌ๋ฆผ ์ฒ˜๋ฆฌํ•ฉ๋‹ˆ๋‹ค. ๋˜ํ•œ ๊ทธ ์ •์ˆ˜ ๊ฐœ์ˆ˜๋กœ ์‹ค์ œ ๋‹ฌ์„ฑ๋˜๋Š” ์กฐ๋„๋„ ํ•จ๊ป˜ ์•Œ๋ ค์ค๋‹ˆ๋‹ค.

๊ณต์‹ ํ’€์ด

ํ•ต์‹ฌ ๊ณต์‹์€ ๋‹ค์Œ๊ณผ ๊ฐ™์Šต๋‹ˆ๋‹ค.

$$N = \left\lceil \frac{\text{Target Lux} \times \text{Area (m}^2)}{\text{Lumens/Fixture} \times \text{CU} \times \text{LLF}} \right\rceil$$

๋ถ„์ž \(E \times A\)๋Š” ์ž‘์—…๋ฉด์— ๋„๋‹ฌํ•ด์•ผ ํ•˜๋Š” ์ด ๊ด‘์†์„ ์˜๋ฏธํ•ฉ๋‹ˆ๋‹ค. ๋ถ„๋ชจ \(\Phi \times \text{CU} \times \text{LLF}\)๋Š” ์กฐ๋ช…๋ฅ ๊ณผ ๋ณด์ˆ˜ ์†์‹ค์„ ๋ฐ˜์˜ํ•œ ๋’ค ๊ธฐ๊ตฌ ํ•œ ๋Œ€๊ฐ€ ์‹ค์ œ๋กœ ๊ธฐ์—ฌํ•˜๋Š” ์œ ํšจ ๊ด‘์†์ž…๋‹ˆ๋‹ค. CU๋Š” ๋ณดํ†ต 0.4~0.8, LLF๋Š” 0.7~0.85 ๋ฒ”์œ„์— ์žˆ์Šต๋‹ˆ๋‹ค.

Annotated formula breakdown showing number of fixtures equals illuminance times area divided by lumens times CU times LLF
Each variable in the lumen method formula: target illuminance E, area A, fixture lumens ฮฆ, coefficient of utilization CU, and light loss factor LLF.

๊ณ„์‚ฐ ์˜ˆ์‹œ

50 mยฒ ์‚ฌ๋ฌด์‹ค์—์„œ 500 ๋Ÿญ์Šค๋ฅผ ๋ชฉํ‘œ๋กœ ํ•˜๊ณ , 3500 lm ๊ธฐ๊ตฌ์— CU = 0.6, LLF = 0.8์„ ์ ์šฉํ•œ ๊ฒฝ์šฐ: ๊ธฐ๊ตฌ๋‹น ์œ ํšจ ๊ด‘์† =

$$3500 \times 0.6 \times 0.8 = 1680$$

ํ•„์š” ์ˆ˜๋Ÿ‰ =

$$\frac{500 \times 50}{1680} = \frac{25000}{1680} \approx 14.88$$

๋กœ, ์˜ฌ๋ฆผํ•˜๋ฉด 15๋Œ€์ž…๋‹ˆ๋‹ค. ๋‹ฌ์„ฑ ์กฐ๋„ =

$$E = \frac{15 \times 1680}{50} \approx 504 \text{ ๋Ÿญ์Šค}$$

๊ฐ€ ๋ฉ๋‹ˆ๋‹ค.

์ž์ฃผ ๋ฌป๋Š” ์งˆ๋ฌธ

์ ์ ˆํ•œ CU ๊ฐ’์€ ์–ผ๋งˆ์ธ๊ฐ€์š”? CU๋Š” ์‹ค๋‚ด ํ˜•์ƒ, ์„ค์น˜ ๋†’์ด, ํ‘œ๋ฉด ๋ฐ˜์‚ฌ์œจ์— ๋”ฐ๋ผ ๋‹ฌ๋ผ์ง‘๋‹ˆ๋‹ค. ์‚ฌ๋ฌด์‹ค์˜ ๊ฒฝ์šฐ 0.5~0.7 ์ •๋„๊ฐ€ ์ผ๋ฐ˜์ ์ž…๋‹ˆ๋‹ค.

์™œ ์˜ฌ๋ฆผ ์ฒ˜๋ฆฌํ•˜๋‚˜์š”? ์กฐ๋ช… ๊ธฐ๊ตฌ๋ฅผ ์†Œ์ˆ˜์  ๋‹จ์œ„๋กœ ์„ค์น˜ํ•  ์ˆ˜๋Š” ์—†์œผ๋ฉฐ, ์˜ฌ๋ฆผ ์ฒ˜๋ฆฌํ•ด์•ผ ์„ค๊ณ„๊ฐ€ ๋ชฉํ‘œ ์กฐ๋„๋ฅผ ์ถฉ์กฑํ•˜๊ฑฐ๋‚˜ ๊ทธ ์ด์ƒ์ด ๋ฉ๋‹ˆ๋‹ค.

LLF๋Š” ๋ฌด์—‡์„ ๋ฐ˜์˜ํ•˜๋‚˜์š”? ๋žจํ”„ ๊ด‘์† ์ €ํ•˜, ์กฐ๋ช… ๊ธฐ๊ตฌ์˜ ๋จผ์ง€ ์ถ•์ , ๋ณด์ˆ˜ ์ฃผ๊ธฐ ๋™์•ˆ์˜ ์ฃผ๋ณ€ ์˜จ๋„ ์˜ํ–ฅ ๋“ฑ์„ ๋ฐ˜์˜ํ•ฉ๋‹ˆ๋‹ค.

์ตœ์ข… ์—…๋ฐ์ดํŠธ: